UNI® – Combine various types of tests to maximize the efficiency at the same time minimize analytical error. It’s a fully-automated Monotest Immunoanalyzer with monotest reagent cartridge.
Less human effort
Wide range of tests
New tests constantly developed
Flexible job list
Rare and routine kits available on one platform
UNI®
The UNI® Monotest Immunoanalyzer is the answer for laboratories of all sizes who demand a flexible solution in total automation of more than 250 different assays.
This easy-to-use, beautifully designed benchtop analyzer provides a perfect fit in your laboratory, and is designed to carry out in vitro diagnostic tests such as Viral, Bacteria and Parasite infections, Cancer and Cardiac markers; Fertility, Steroids, Anemia, Thyroid kits, etc., just in a few steps.
All reagents needed to perform tests are incorporated in a single ready-to-use barcoded cartridge.
Up to 30 different assays can be performed simultaneously in one cycle.
The UNI test method is EIA, as the well proved gold standard.
30 positions in temperature Peltier controlled (25-37°C) rotor ensure perfect conditions for 30 different assays in one run.
Perfect mixing is ensured by 2 vibration motors.
Conjugate has its own dedicated probe to minimize risk of cross contamination, together with dedicated piercing device for easy and risk free handling of reagents.
UNI reduces carry-over with 2 independent sets of probes and piercing devices coated with the latest technology nanoceramic.
The Reagent level is constantly being monitored by intelligent software and measured by precise weight sensors, which is more reliable than liquid level sensor monitoring.
The Optical systems are advanced LED fiber optics – maintenance free. No need for lamp change and difficult adjustments by specialized service engineers.
Capacitive level sensor probes for accurate reagent handling.
Ceramics pump with high precision step motor (1 step = 0.01187 μL) is maintenance free.
INDEX
PERFORMANCE
Sample positions
30
Sample volume
Minimum 20μL (check instructions for each use)
Reaction temperature
25±0.5°C or 37°C±0.5°C
Assay Method
EIA
Assay Speed
(60-120) min / 30 tests
Calibration
Calibrator included in all regent kits
Quality Control
Internal QC material included in all regent kits
Test Combination
Different tests with the same reaction temperature
Photometer Light Source
LED
Filters
450 nm / 630 nm
OD Resolution
0.001ABS
Range of OD
0.000 ~ 3.000ABS
Accuracy of Filters
≤±3 nm
Half width of Filters
≤12 nm
Linearity of OD
0.000 – 3.0000A r0.98
Repeatability of OD
CV≤5%
Accuracy & Fluctuation of Temperature
When operating at 25°C, offset ≤±0.5°C, Fluctuation ≤±0.4°C
Carry-over
≤1%
Accuracy and Precision of Priming
Offset ≤±5%, CV≤2%
Noise
<80dB
Dimensions/Weight
680mm x 600mm x 500mm / 48kg
Voltage
AC 100-240V
Frequency
50/60Hz
Maximum power
350VA